Wipe the exterior cover clean with a damp cloth. Ensure the test/monitoring wires are correctly mapped to your door controller, or check if the door controller monitoring settings match the sensor output. Sensor does not detect pedestrians close to the threshold
The integrated LED provides instant feedback on the sensor's status: 🟢 Green: Standby mode (Operational). Infrared (AIR) safety curtain triggered. 🟡 Yellow: Radar (Motion) detection triggered. 🔵 Blue: Configuration mode or internal test phase. ⚪ Flashing Red: Fault detected / Error state. ⚙️ Configuration & Adjustment The unit is typically adjusted using internal DIP switches remote control 1. Motion Detection (Radar) You can adjust the radar field to be wide or narrow. Sensitivity:
: Adjust the infrared curtain angle (typically -4∘negative 4 raised to the composed with power +4∘positive 4 raised to the composed with power
Use the manual adjustment screw to align the safety curtain. The safety field must look directly downward, passing immediately in front of the moving door leaf without hitting the door itself. 5. Setup and Calibration Routine
The official manual is structured to guide you from unboxing to advanced troubleshooting. Here are the core chapters you should study first: prosecure opti combi manual english
This public link is valid for 7 days and shares a thread, including any personal information you added. This link or copies made by others cannot be deleted. If you share with third parties, their policies apply. Can’t copy the link right now. Try again later.
This comprehensive English manual provides step-by-step instructions for installing, programming, and troubleshooting your ProSecure Opti Combi sensor to ensure peak performance and long-term reliability. 1. Product Overview and Technical Specifications
To meet or DIN 18650 standards, the infrared safety curtain must be tested daily. The Prosecure Opti Combi features a self-monitoring "Test Input" that the door controller uses to verify the sensor is functional before every closing cycle.
Configures monitoring feedback to match the door controller. 7. Troubleshooting Common Error Codes Wipe the exterior cover clean with a damp cloth
Motion relay (Type A) and Safety relay/opto-coupler Temperature Range: -20°C to +55°C (-4°F to 131°F) IP Rating: IP54 (dust and splash-proof) 2. Pre-Installation and Mounting Instructions
It is recommended to perform a walk-test at least once a year to ensure the safety curtain correctly detects objects in the threshold prosecure opti combi
Combines a microwave radar (activation) and an active infrared curtain (protection/safety) in a single unit. Primary Use: Designed primarily for automatic sliding doors
Ensure there is at least 50mm of clearance above the sensor to allow the cover to clip off easily. Step 2: Drilling Tape the included mounting template to the header profile. Infrared (AIR) safety curtain triggered
Toggles automatic environment relearning profiles. (Standard / Eco) 6. Troubleshooting Common Issues The door keeps recycling (opening and closing indefinitely) The sensor sees the door panels moving or vibrating.