| Alternative | Cost | Best For | | :--- | :--- | :--- | | (4‑client limit) | Lower than Gateway | Small SCADA systems with ≤4 operator stations | | FactoryTalk Linx Gateway (newer, replaces Classic) | Similar pricing | Modern ControlLogix 5580 & PlantPAx | | Ignition OPC Server (by Inductive Automation) | Free trial, then subscription | Cross‑platform, non‑Rockwell PLCs | | Kepware (KEPServerEX) | Paid (per driver) | Mixed vendor environments (Siemens + AB) |
From the Available Driver Types dropdown, select . Click Add New and name the driver.
Right-click the downloaded setup file ( Setup.exe ) and select Run as Administrator . rslinx gateway download
Use the FactoryTalk Activation Manager to activate your software license. Reboot: Restart your computer to complete the installation. RSLinx Gateway vs. Other Editions
You cannot run Gateway side‑by‑side with RSLinx Lite or Single Node on the same PC. Uninstall the other version first (back up your driver configuration: C:\RSLinx\*.rsh files). | Alternative | Cost | Best For |
Imagine you are an automation engineer tasked with connecting a remote office to the factory floor. You don't just need a local driver; you need the
Access to these files requires a Rockwell Automation Support account and valid software activation (license) for RSLinx Gateway. Installation and Configuration Tips Use the FactoryTalk Activation Manager to activate your
RSLinx Gateway, a premium tier of the software suite by Rockwell Automation, is an essential communication server for large-scale industrial networks. Unlike the free "Lite" version, RSLinx Gateway enables remote OPC (OLE for Process Control) connectivity, allowing a single server to bridge communications between multiple workstations and plant-floor devices. Core Functionality of RSLinx Gateway
Provides a high-speed interface for third-party HMI and SCADA systems.
Don't try to "download a Gateway." Instead, open RSLinx, go to Communications → Configure Drivers , and add an Ethernet/IP Driver . This allows you to browse for your PLC correctly without needing the expensive Gateway license. 4. Summary Table RSLinx Lite (Free) RSLinx Gateway (Paid) Download PLC Programs Yes (Locally) Yes (Remote & Local) Remote OPC Support Bridge Connections Cost Requires License Key
Note: In modern Rockwell architectures, "RSLinx Gateway" is often replaced by for faster performance with newer controllers, but RSLinx Classic Gateway remains crucial for legacy systems and specialized communication protocols. Key Features & Benefits