Erhardt-leimer Do 3001 Manual Work 【2026】
By default, the DO 3001 is an edge guide. But Section 5.3 shows how to switch to using P-03 = 2. You will need two sensors (left and right) connected via a Y-cable. The manual provides the wiring diagram on page 34.
acts as the primary "brain" or interface between the human operator and the web guiding hardware. While the physical correction is handled by actuators (like pivoting frames) and monitored by sensors (infrared or ultrasonic), the DO 3001 allows for: Operating Modes : Switching between guiding modes. System Networking : It typically connects via a
Check electrical cable connections for wear, fraying, or loosening due to machine vibration.
The touch‑screen allows direct entry of values and configuration of up to 12 digital inputs, which can be used for external commands such as:
. Even minor deviations in a moving web can lead to material waste, machine downtime, or poor-quality finished products (like misaligned printing or uneven rolls). The digital nature of the DO series allows for high control dynamics, ensuring that corrections happen in fractions of a second even at high line speeds. of the manual, such as the wiring diagrams error code troubleshooting Web guiding systems - Erhardt+Leimer Erhardt-leimer Do 3001 Manual
Check 24V supply; Verify safety interlocks; Manually center the mechanism. Proportional Gain ( Kpcap K sub p ) is set too high; Sensor response time lag.
Activate the "Automatic" mode to begin web guiding.
The system utilizes two sensors to track both edges simultaneously, ensuring the centerline of the material remains fixed, even if the material width fluctuates.
P-25 and P-26 allow software limits, so the actuator never physically hits the hard stops, increasing longevity. Many users ignore this until they read Section 6.5. By default, the DO 3001 is an edge guide
Designed for compatibility with ELGUIDER and other modular components. 2. Installation and Initial Setup
In the high-speed world of web processing—whether you are handling paper, film, foil, or textiles—edge control and web guiding are non-negotiable. One of the most legendary names in this industry is . Among their extensive catalog, the Erhardt-Leimer DO 3001 stands out as a robust, reliable, and sophisticated web guiding controller.
Without the manual, you might think the controller is broken when it hasn't been taught.
| Parameter | Value | |-------------------------|-------------------------------------------------------------------| | | 24 V DC (nominal range 20–30 V DC) | | Current consumption | AG 91: 6 A AG 93: 8 A | | Ambient temperature | 0 … 50 °C | | Protection class | IP 54 | | Dimensions | Housing 135.5 × 135.5 × 100 mm Panel cut‑out 124 × 124 mm | | Weight | approx. 0.6 kg | | Sensor connections | 2× edge sensors (MB SensorCAN) 1× line sensor | | Interface to actuator | Ethernet (1 ms response) and power supply | | Interface to customer | 12 digital inputs, 2 digital outputs | The manual provides the wiring diagram on page 34
Erhardt+Leimer DO 3001 Digital Control Command Station: A Comprehensive Guide
Check M12 cabling. Verify the CAN termination resistors are properly positioned in the network. Ambient light interference or heavy machine vibration.
The system is designed to be low-maintenance, but in case of issues, the DO 3001 display shows error codes. Common troubleshooting steps involve: