Deckma OMD-11 Bilge Alarm Monitor Go to product viewer dialog for this item. : A Comprehensive Manual & Guide The Deckma OMD-11
: Designed to minimize false readings caused by non-oil contaminants like iron oxide, showing only 2 ppm for substances that older monitors might misread as 15 ppm. Dual Alarms
: Test the unit weekly using clean, oil-free water. deckma omd11 manual
They are preset at 15 ppm but can be readjusted to lower levels (e.g., 5 ppm or 10 ppm) to suit specific requirements. An alarm setpoint above 15 ppm is not permissible. 4. Maintenance and Troubleshooting Regular maintenance of the Deckma OMD-11 is vital for accurate measurements and longevity. 4.1 Safety Hazards
is a vital piece of marine safety and environmental equipment engineered by Deckma Hamburg GmbH . Designed specifically for use with 15 ppm (parts per million) Oily Water Separator (OWS) units, the OMD-11 ensures compliance with strict international maritime pollution regulations. It measures the concentration of oil in bilge water discharge, preventing accidental pollution by triggering alarms and stopping overboard discharge if legal limits are exceeded. Deckma OMD-11 Bilge Alarm Monitor Go to product
: Suitable for sample water temperatures between +1°C and +60°C and designed with an IP 65 protection rating for harsh marine conditions. Installation & Maintenance Highlights
Sensors measure the amount of light scattered by oil droplets in the water. They are preset at 15 ppm but can
Periodically flush the unit with clean, oil-free water to verify the "Zero" reading.