Complete Technical Manual Guide: Yaohua XK3190-C801 Weighing Indicator

Are you trying to program a specific (e.g., 2-speed packing, loss-in-weight feeding)?

Do you still need help with a specific error code or setting? Leave a comment below (monitored daily by volunteer scale technicians), or refer to Section 7.5 of the manual for technical support hotlines in your region.

Enter your scale's maximum rated capacity (e.g., 050000 for 50,000kg). Press to confirm. Step 5: Zero Calibration (Zero Point Set) Ensure the scale platform is entirely empty. The display will read [ nOAD ] or [CAL 0] . Wait for the [ Stable ] indicator light to turn on.

Input the maximum weight capacity of your scale using the numeric keys. Press to confirm. Step 4: Zero Point Calibration

The C801 requires calibration to operate accurately. The manual outlines the two main methods: Setting the "no-load" point. Span Calibration: Setting the reference weight point. D. Parameter Setting (Parameter Table)

Return the calibration switch to its original position to lock the settings. Troubleshooting and Error Codes

Locate the calibration switch or plug on the rear panel. Turn the switch to the "ON" or "Allow" position. Press the or [Set] key while turning on the power. Step 2: Zero Calibration The display will show [-] Cal 0 . Ensure the scale is completely empty and stable. Press the [Enter] key.

The XK3190-C801 stands out in industrial environments due to its versatile programming features.

The manual is listed under "XK3190-C8 weight Instruction Implement Manual".

Restart the indicator. If the error persists, the internal memory chip requires replacement. OL (Overload)

Standard 5-pin or 9-pin connector. Connect Excel (+E), Excitation (-E), Signal (+S), and Signal (-S). Always use shielded cables to avoid electromagnetic interference.

series. Whether you are setting up a new batching system or troubleshooting an existing one, having the right manual is the first step toward precision.

: Detailed specifications for the higher-end controller version can be found on Kuanyi . Instruction Implement Manual

Monitors objects passing over a dynamic catch scale. It triggers alarms based on predefined maximum and minimum tolerances. ⚡ Wiring and Interface Connections

The back panel of the indicator provides robust communication and control terminal interfaces. Load Cell Connection

is or explosion-proof. Keep it away from direct sunlight, serious dust, and moisture. Where to Find the Full Manual

Yaohua XK3190-C801 is a high-performance weighing transmitter and indicator designed for industrial control systems like batching scales and catchweighers. A standout feature is its ultra-thin, rail-mounted design (35mm thickness)