If only patching GI (not RAC homes), use the -oh option to specify the Grid Home.

Non-rolling mode is the more conservative approach, designed for stability and consistency. It requires a full cluster outage, making it a "big bang" operation that affects the entire cluster at once.

/u01/app/19.0.0/grid/OPatch/opatchauto apply /soft/35319490 -nonrolling Start the Stack

If the previous rolling attempt left a partial session, opatchauto might try to resume in rolling mode. You may need to update the session configuration file located in $GRID_HOME/OPatch/auto/dbsessioninfo/ . Open the JSON file for the failed session ID.

GI Stack must be on this specific local node initially to read configurations. Phase 2: Shutdown / Remote Stop Remote Nodes (Nodes All remote nodes must be stopped and completely offline. Phase 3: Execution / Patching Shared / Consolidated Environment opatchauto72030 execute in nonrolling mode exclusive

The error is a sign that the automated "Exclusive" lock required for a non-rolling patch cannot be safely established. By checking the deep logs and verifying that the GI stack can be stopped manually, you can usually bypass the automation hurdle and successfully update your environment.

It applies the designated binary patches to both the GI home and the Database homes.

To resolve this issue successfully and ensure complete cluster parity, DBAs must switch strategies and . Root Cause Analysis 1. Shared Cluster Homes ( ORACLE_HOME / Grid Home)

The opatchauto utility is Oracle’s automation tool for patching GI (Grid Infrastructure) and RAC (Real Application Clusters) homes. It orchestrates the complex process of stopping services, applying binary patches, and restarting services across multiple nodes. If only patching GI (not RAC homes), use

Before attempting to re-run a non-rolling patch, ensure the Grid Infrastructure stack is in the exact state required by the patch documentation.

OPatchAUTO72030 is an Oracle patching operation identifier that appears when using Oracle OPatch/OPatchAUTO to apply patches to Oracle Grid Infrastructure, Oracle Home(s), or database homes. The operation involves applying rolling or nonrolling patches; the message or error referencing OPatchAUTO72030 typically arises when OPatchAUTO is instructed to execute in nonrolling mode with exclusive resource locks, or when a patch cannot be applied in rolling mode and OPatchAUTO switches to or requires nonrolling (exclusive) mode.

This error indicates that opatchauto detected a , which makes traditional rolling patching impossible. This article explains the cause of the OPATCHAUTO-72030 error, why non-rolling mode is required, and provides a step-by-step guide to executing the patch in non-rolling mode, including the necessary exclusive actions. What Causes OPATCHAUTO-72030? Oracle RAC patching typically happens in one of two modes:

You are instructing the utility to:

Troubleshooting Common Edge Cases During Non-Rolling Patching

Once the analyzer confirms readiness, execute the core patching binary payload natively via the command-line terminal:

When used correctly, non-rolling exclusive mode simplifies patching and reduces total maintenance time. When misused, it can lead to extended downtime. Always respect the patch README and Oracle’s rolling/non-rolling guidelines.